Maintenance Object Repair Procedures
Page 10-1460TIE-TRK (Tie Trunk)
10
1000 ABORT System resources required to run this test are not
available. The trunk may be busy with a valid call. Use
the display trunk xx command to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, the port
is unavailable for certain tests. (Refer to the "Status
Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the
port is idle before retesting.
1. If the port status is active, but the port is not in use
(no calls), check the Error Log for Error Type 1025
(see Error Log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at
one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not
handling heavy traffic, repeat test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-443. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation