DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1476TIE-TRK (Tie Trunk)
10
1901 ABORT This error occurs when the TN771 circuit pack uplinks a
message that is not the proper response for this test.
The anticipated uplink messages are seize, ring or
answer.
1. Verify that the Trunk is administered properly.
2. If the test continues to abort, escalate the problem.
1905 ABORT Intercept tone detected from far end.
1. Get the test line data from theand verify it with the far
end. Dial the test number manually to see if the TTL
is reached. If it is not, then either the number is
wrong, or the far end is administered incorrectly.
2. If the test continues to abort escalate the problem.
1906 ABORT Reorder tone detected from far end.
1. See actions for error code 1905.
1907 ABORT Other unexpected tone detected from far end.
1. See actions for error code 1905.
1913 ABORT Audible Ring detected from far end.
1. See actions for error code 1905.
1914 ABORT Unidentified interrupted tone detected from far end.
1. See actions for error code 1905
1915 ABORT Busy tone detected from far end.
1. Since the test line at the far end was busy. Try the
test again.
2. If the test continues to abort, the problem is with the
far end system.
1918 ABORT Test progress tone not removed from far end (type 105
test line only).
1. The problem is with the far end system; a technician
at the far end should test the test line (TN771 or
ADFTC).
Table 10-447. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page