Maintenance Object Repair Procedures
Page 10-970M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Table 10-279. TEST #13 Digital Port Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port is in use on a valid ISDN-PRI Test Call. Use the
list isdn-testcall command to determine which call is
using the port (from the M/T Port column). Either wait for
the test call to complete (as indicated in the Start Time
and Duration fields in the above display), or abort the
test call with the clear isdn-testcall tg/mem command,
where tg/mem is determined from the B-channel field of
the above display.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1001 ABORT System resources required to run this test are not
available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page