Maintenance Object Repair Procedures
Page 10-677EXP-INTF (Expansion Interface Circuit Pack)
10
1002 ABORT The system could not allocate time slots for the test on either TDM
Bus. The system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to TDM-BUS
(TDM Bus) Maintenance documentation to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, repeat the test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If these errors are
present, refer to TTR-LEV (TTR Level) Maintenance
documentation. Even if there are no TTR-LEV errors, there still
may not be a Tone Detector available on the network that contains
the circuit pack being tested. Verify that there is at least one Tone
Detector on this network. If not, this test always aborts for this
Expansion Interface circuit pack. This does not harm the system
in any way.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1031 ABORT A query of the Expansion Interface circuit pack aborted. The purpose
of this query was to see if the Expansion Interface circuit pack could
detect the framing signal.
1. If Test #238 aborted, follow the procedure associated with this
abort code.
2. If Test #238 did not abort, rerun Test #240 at 1-minute intervals a
maximum of 5 times.
3. If Test #240 continues to abort without Test #238 aborting,
escalate the problem.
1032 ABORT The Expansion Interface circuit pack cannot detect the framing signal
and cannot run the test.
1. Refer to the errors for Test #238 to determine why the Expansion
Interface circuit pack is out-of-frame.
Table 10-193. TEST #240 EI Local Loop Around Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page