Maintenance Commands and Trouble-Clearing Aids
Page 8-576test eda-external-device-alrm
8
For the following output example, assume that the command that was entered
was "test duplication-interface 1A" while "A" was the active carrier in an SPE
duplex system.
Feature Interactions
Failures of the duplication-interface may prevent SPE switching.
test eda-external-device-alrm
test eda-external-device-alrm all | physical location [ repeat number | clear ][
schedule ]
This test will perform hardware diagnostic tests on an individual
external-device-alarm port or on all external-device-alarm ports.
The test eda-external-device-alrm command performs a hardware diagnostic
test on all administered external device alarms if all is entered. If an administered
external device alarm port is entered, the test external-device-alarm command
performs a hardware diagnostic test on that port. The test PASSES if the external
device is not reporting an external device alarm and FAILS if the external device
is reporting an external device alarm. If the technician specifies the port it must
be administered as an external device alarm port on a maintenance board or on
an analog line port carrier board.
test duplication-interface a long SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
1A SHDW-CIR 285 PASS
1A SHDW-CIR 283 PASS
1A SHDW-CIR 284 PASS
1A SPE-SELE 278 PASS
1A DUPINT 315 PASS
1A DUPINT 275 PASS
1A DUPINT 276 PASS
1A DUPINT 280 PASS
1A DUPINT 271 PASS
1A DUPINT 277 PASS
1A DUPINT 272 PASS
1A DUPINT 274 PASS
1A DUPINT 273 PASS
Command Successfully Completed