Table 10-457. TEST #52 Control Channel Loop Around Test
Error
Code
Test
Result Description/ Recommendation
None
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The circuit pack failed to return the circuit pack code or
vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is
one of the Port circuit packs, replace the circuit
pack. Otherwise, if the circuit pack is part of the
SPE, use the procedure described in ‘‘
Replacing
Defective SPE Circuit Packs’’ in Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’.
3. Retry the command a few times a maximum of 5
times.
4. If the test continues to fail, escalate the problem.
PASS Communication with this circuit pack is successful.