Maintenance Object Repair Procedures
Page 10-858MAINT (EPN Maintenance Circuit Pack)
10
on the terminal while the test is running is lost. Figure 10-63 shows the three
serial interfaces on the EPN Maintenance circuit pack and is meant to clarify that
only the one dealing with the EPN terminal is being tested.
Figure 10-63. EPN Manager I (G1) or G3MT Connection
Table 10-242. TEST #228 MGR I Channel Local Loop Around Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2034 ABORT Background EPN Maintenance circuit pack maintenance is running the
MGR I Channel Local Loop Around Test.
1. Wait 30 seconds and retry the test a maximum of 5 times.
22801 ABORT Test disabled via software patch.
Continued on next page
ACTIVE LINK
STANDBY LINK
EXPANSION INTERFACE
CIRCUIT PACK
M
G
R
1
EPN MAINTENANCE CIRCUIT PACK
SERIAL INTERFACES
MGR 1 SERIAL
INTERFACE