DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1499TONE-BD (Tone-Clock Circuit Pack)
10
■ SYSFM
■ SYSDCLK
If this data indicates this Tone-Clock circuit pack had a loss of any of these
clocks, the inquiry reports FAIL. In addition, if TDM-CLK error 1 is at threshold,
this test will FAIL. TDM-CLK error 1 indicates a suspect clock is at the edge of its
specified frequency. If the circuit pack did not have a loss of clock or TDM-CLK
error 1 at threshold, the inquiry reports PASS.
This is not really a test, in the sense that it simply reports status held by the
system, and does not generate new information or raise alarms. If this test fails
with no error code, there is at least one Major alarm against a Tone-Clock circuit
pack. If this test fails with an error code of 1, there is at least one Minor off-board
alarm against a TDM-CLK.
Table 10-449. TEST #46 Clock Health Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at 11-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, follow normal
escalation procedures.
Continued on next page