Maintenance Object Repair Procedures
Page 10-451DID-TRK (DID Trunk)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present or some Tone Detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the station extension, attendant
number, or trunk group/member number of the port. Use
the status station, status attendant, or status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is
not busied out.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
Table 10-124. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page