Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-990OPS-LINE (DS1 OPS Line)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
tone detectors present or some of the tone detectors
may be out of service. Issue the list measurements
tone-receiver command to display basic information
about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present,
refer to the TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present,
refer to the TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute
intervals for a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use
status station or status trunk command to determine
when the port is available for testing.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1018 ABORT The test was disabled via translation.
1. You may want to determine why the test has been
disabled before you enable it.
2. To enable the test for the particular analog station
being tested, enter the ’change station extension’
command, and then change the ’Test’ field on the
’Station’ form from ’n’ to ’y.’
Table 10-286. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page