Maintenance Object Repair Procedures
Page 10-1266STBY-SPE (Standby SPE)
10
Note that the busyout spe-standby and release spe-standby
commands do not affect alarms on other Maintenance Objects in
the standby processor complex.
2. If some of the tests fail, refer to the appropriate MO section and
follow the procedures described there.
The following table summarizes the error types that may affect the
functionalities of the Communication Path to the Standby SPE and of
Memory Shadowing. To restore the function, all error types that may affect
the function must be investigated and resolved by following the
recommended commands or procedures.
o. Error Type 801 is logged when the upgrade software command failed
due to the loss of communication with the Standby SPE during the
upgrade. This implies that the software reprogramming of the Standby
SPE never completed.
The upgrade software command should be re-executed. If it fails again,
the Standby SPE Processor circuit pack should be replaced.
p. Error Type 802 is logged when the upgrade software command failed
due to the bad flash checksum on the Standby SPE after the completion of
the upgrade. This implies that the on-board flash memory may not be
functional. The Standby SPE is running the new software while the Active
SPE is still running the old software. However, due to the bad flash
checksum, the behavior of the Standby SPE may be unpredictable.
The upgrade software command should be re-executed. If the command
fails again, the Standby SPE Processor circuit pack should be replaced.
q. Error Type 803 is logged when the upgrade software command failed
due to the failure to insert the translation card-mem into the Standby SPE
in time during the reboot immediately following a successful upgrade. This
implies that the Standby SPE is running the new software while the Active
SPE is still running the old software.
The translation card-mem should be inserted into the Standby SPE at the
appropriate time so as to allow the upgrade software command to be
re-executed.
Function Affected Error Types
Communication Path To
Standby SPE
58, 80, 81, 98, 99, 106, 1 with Aux Data
values 2016, 2017, 2022, 2024, or 2025; 139
with Aux Data value 2015.
Memory Shadowing 67, 82, 85, 106, 257 with Aux Data values
2014, 2015, 2021, 2024, 2048, 2049, 2050,
or 2051.