DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-651test shadow-link
8
Synopsis
test shadow-link
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician,
inads, init.
Examples
test shadow-link l
test shadow-link sh r 2
test shadow-link sh r 2 schedule
test shadow-link c
Description
The test shadow-link command performs hardware diagnostics for the shadow
link between the two duplication-interface circuit packs. This command works
only with a High or Critical Reliability System. Refer to Chapter 6, ‘‘
Reliability
Systems: A Maintenance Aid’’ for more details.
Defaults
The default for the command is short with the repeat of 1.
Parameters
short The short and long test sequence both execute only test #318.
long The short and long test sequence both execute only test #318.