DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-56change synchronization
8
Description
A hierarchy of sources exists within each system that are used for timing
synchronization. For stratum 3 synchronization, this hierarchy is reflected by the
DS1 inputs to the external stratum 3 clock. For stratum 4 synchronization, this
hierarchy is reflected in the primary and secondary fields. If all fields are blank,
then the tone clock board within each PN provides timing for that PN.
Defaults
None.
Parameters
None.
Help Messages
If the user presses HELP after entering "change synchronization" the following
message is displayed:
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict.