DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-901MET-LINE (MET Line)
10
Table 10-257. TEST #61 MET Line Station Audits Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1 ABORT The test was aborted due to an internal system error
during the switchhook audit.
2 The test was aborted due to an internal system error
during the bad scan inquiry.
3 The test was aborted due to an internal system error
during the EPF audit inquiry.
1. Make sure that the station is not in an out-of-service
state.
2. Retry the command at 1-minute intervals for a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use
the display port PCSSpp command to determine the
station extension, attendant number, or trunk
group/member number of the port. Use the status
station, status attendant, or status trunk command to
determine the service state of the port. If the service
state indicates that the port is in use, then the port is
unavailable for certain tests. (Refer to the "Status
Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is
not busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page