DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-465DIG-BD (Digital Line Circuit Pack)
10
DIG-BD (Digital Line Circuit Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DIG-LINE (Digital Line) Maintenance
documentation for related line information.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the
carrier where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name As
It Appears in
Alarm Log
Alarm
Level
Initial System
Technician
Command to Run
1
Full Name of MO
DIG-BD MIN test board PCSS sh Digital Line Circuit Pack
DIG-BD WRN test board PCSS sh Digital Line Circuit Pack