Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-713EXT-DEV ADMIN? Y (External Device Alarm)
10
EXT-DEV ADMIN? Y (External
Device Alarm)
NOTE:
Use this Maintenance Object when the
External Device Alarm Admin?
field
on the
change system-parameters customer-options
form is set to (y). You
must have INADS or INIT login permission to administer EXT-DEV Alarm.
Generic 3i Maintenance circuit packs each have alarm leads which can be
connected to external devices such as Uninterruptible Power Supplies (UPS) or
adjuncts such as AUDIX. Certain conditions on the external device close the
contacts on the alarm leads to notify the switch which in turn originates an
EXT-DEV alarm.
The special locations UUmajor and UUminor are used to designate the major or
minor maintenance board alarm connection for cabinet UU. The major/minor
designation specifies the port, not the alarm level associated with the
connection;
for example,
the “major” port can be administered as a major, minor,
or warning alarm, and the “minor” port can be administered as a major, minor or
warning alarm. In addition Analog line ports can also be administered as external
device alarms.
NOTE:
An unadministered maintenance board external device alarm port, that is
sensing a contact closure will have an entry in the Error Log and in the
Alarm Log. INADS will not receive warning alarms.
In the Standard Reliability PPN the Maintenance Processor (TN786B or TN790) in
carrier (A) monitors the EXT-DEV alarm leads. In the High or Critical PPN, the
1. where UU is an appropriate cabinet number determined via the PORT field from the Alarm or
Error Log.
MO Name As
It Appears in
Alarm Log
Alarm
Level
Initial System Technician
Command to Run
1
Full Name of MO
EXT-DEV MAJOR test
eda-external-device-alrm
physical location
External Device Alarm
EXT-DEV MINOR test
eda-external-device-alrm
physical location
External Device Alarm
EXT-DEV WARNING test
eda-external-device-alrm
physical location