Maintenance Object Repair Procedures
Page 10-1502TONE-PT (Tone Generator)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See ‘‘
How to Replace a
Tone-Clock Circuit Pack’’ in the TONE-BD section.
b. The indicated Tone-Clock circuit pack has been made unavailable via the
busyout tone-clock PC command. It only applies to systems which have
the High or Critical Reliability Option administered, because only a
standby Tone-Clock circuit pack may be made busy by that command. To
resolve this error, execute the release tone-clock PC command for the
alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. The tone generation facility is having problems verifying that tones have
been connected as requested.
e. The tone generation facility may or may not be able to generate tones.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Tone Generator Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test tone-clock PC r 1
1(a) 17664 Tone Generator Audit/
Update Test (#41)
MAJOR/
MINOR
ON test tone-clock PC r 2
18(b) 0 busyout tone-clock PC WARNING OFF release tone-clock PC
130(c) None MINOR ON test tone-clock PC Sh
257(d,f) 17667 None MINOR ON
513(e,f) 17666 Tone Generator Audit/
Update Test (#41)
MINOR ON test tone-clock PC r 3
769 Any Transmission Test (#40) MAJOR/
MINOR
ON test tone-clock PC r 3
1025 Crosstalk Test (#90) MAJOR/
MINOR
ON test tone-clock PC l r 2
1281(g) Any Tone Generator Audit/
Update Test (#41)