DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1335SYNC (Synchronization)
10
5.Standard system:—Error 2305:
Replace the Expansion Interface circuit pack in this port
network and the Expansion Interface circuit pack in the PPN
that is connected to this port network.
If the problem persists, replace the Tone-Clock circuit pack
in the slave port network. Follow the steps listed in
“TDM-CLK” to replace the Tone-Clock circuit pack.
i. Noise on the DS1 line can cause transient alarms on synchronization.
Therefore, when a synchronization problem occurs causing error types 1,
257, or 513, a WARNING alarm is first raised for 15 to 20 minutes before
the alarm is upgraded to a MAJOR or MINOR alarm.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Test Synchronization Test,
for example, you may
also clear errors generated from other tests in the testing sequence.
Test Synchronization Test (#417)
This test updates all the Synchronization Maintenance component circuit packs
with the correct information regarding their role in providing synchronization for
the system. All the Tone-Clock, Expansion Interface, and DS1 Interface circuit
packs in the system are updated via this test. This test will either pass or abort.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Test Synchronization Test (#417) X X ND
Table 10-403. TEST #417 Test Synchronization Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page