Maintenance Object Repair Procedures
Page 10-1452TIE-TRK (Tie Trunk)
10
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command. If the MINOR alarm is not downgraded by the set options values, the MINOR alarm is upgraded to
a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
2. Non-TN497 circuit packs only.
3. TN439 circuit packs only.
4. Non-TN439 and non-TN497 circuit packs only
5. TN497 circuit packs only.
6. TN439 and TN497 circuit packs only.
1281
4
Any
4
EPF M and E Lead
(#74)
4
MAJ/MIN/
WRN
1,4
ON
4
test port PCSSpp sh r
3
4
1537 Loop Around and
Conference (#33)
MAJ/MIN/
WRN
1,4
;
MINOR
6
ON test port PCSSpp l r 3
1793 Tie Trunk Seizure
(#73)
4
; Seizure
(#73)
5
; Tie Trunk
Dial (#747)
3
MAJ/MIN/
WRN
4,6
;
MINOR
OFF test port PCSSpp sh r
2
4
; test port PCSSpp s r
2
6
2049 NPE Crosstalk (#6) MAJ/MIN/
WRN
1
,
4
;
MINOR
6
ON test port PCSSpp l r 3
2
2305 (m) 50944 None
4
; Seizure
(#73)
5
; Tie Trunk
Dial (#747)
3
2305
(m)
3
57424
3
Tie Trunk Dial
(#747)
3
2561
5
0
5
None
5
v WARNING
5
OFF
5
2817
5
0
5
None
5
MINOR
5
OFF
5
3073
5
0
5
None
5
3840 (n) 8000 Analog
Transmission
(#844-848)
OFF
3841 (n) Analog
Transmission
(#844-848)
MINOR OFF test analog testcall
PCSS pp r 2
Table 10-441. TIE Trunk Error Log Entries — Continued
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page