DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-321CO-DS1 (DS1 CO Trunk)
10
PASS Trunk translation has been updated successfully. The
current trunk states kept in the DS1 Interface circuit
pack and switch software are consistent. If the trunk is
busied out, the test does not run, but returns to PASS. To
verify that the trunk is in-service:
1. Enter status trunk command to verify that the trunk
is in-service. If the trunk is in-service, no further
action is necessary. If the trunk is out-of-service,
continue to Step 2.
2. Enter release-trunk command to put trunk back into
in-service.
3. Retry the test command.
Table 10-90. TEST #36 Port Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page