Page 10-1184PROCR (Processor Circuit Pack)
10
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when you are
inspecting errors in the system. By clearing error codes associated with the
Processor Non-maskable Interrupt Test,
for example, you may also clear errors
generated from other tests in the testing sequence.
Notes:
a. Refer to PR-MAINT (Maintenance/Tape Processor) Maintenance
documentation for a description of these tests.
b. Refer to MEMORY [386 systems only] Maintenance documentation for a
description of these tests.
Processor Software Initiated Interrupt Test (#77)
This test is a nondestructive test. The test verifies if the 80286/386 Processor can
exercise the three types of software-initiated interrupts:
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Processor Non-maskable Interrupt Test (#82) X X ND
Processor ROM Checksum Test (#80) X X ND
Processor Software Initiated Interrupt Test (#77) X X ND
Processor Sanity Timer Test (#83) X D
MTP Outpulse Relay Test (#102) (a) X X ND
MTP Analog Loop Around Test (#103) (a) X X ND
MTP Sanity Handshake Test (#106) (a) X X ND
MTPSAT Loop Around Test (#228) (a) X X ND
MTP Aux Loop Around Test (#229) (a) X X ND
MTP Reset Test (#101) (a) X D
MTP Dual Port Ram Test (#104) (a) X D
Read All Memory Test (#85)(b) X ND
Memory Error Detection Test (#87)(b) X X ND
Text Checksum Test (#86)(b) X ND
Memory Functional Test (#332) (c)(b) X D
Memory Board Check Test (#631) (b) X X ND