DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1490TONE-BD (Tone-Clock Circuit Pack)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test tone-clock PC sh
1(a) 0 Circuit pack
removed or SAKI
Sanity Test (#53)
MINOR ON
18(b) 0 busyout tone-clock
PC
WARNING OFF release tone-clock PC
23(c) 0 None WARNING OFF
125(d) None MINOR ON
126(e) None MINOR ON
257 65535 Control Channel
Test (#52)
MINOR ON test tone-clock PC r 20
257(f) Any None
513(g) Any None
769(h) 4358 None
1025(i) 4363 NPE Audit Test (50) test tone-clock PC sh
1538(j) Any None MINOR ON
2049(k) 0 Clock Health Inquiry
Test (#46)
MAJOR ON set tone-clock PC
override
2305(k) 0 Clock Health Inquiry
Test (#46)
MAJOR ON set tone-clock PC
override
2561(l) Any None MAJOR ON
3329(m) 0 None MINOR/
WARNING
2
OFF set tone-clock PC
3840(n) Any None
3848(o) 0 Clock Health Inquiry
Test (#46)
set tone-clock PC
override
3872(p) 0 None set tone-clock PC
override
3999 (q) Any None