DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-319reset interface
8
Parameters
Help Messages
If you press HELP after entering "reset interface," the following message displays:
Enter identifier: [cabinet(1)];carrier(A-B);position(1-2)
Error Messages
If the specified carrier is not the active PE, the following message will be
displayed:
Command must be executed from active SPE
If the technician-entered cabinet and carrier is invalid for a PPN, the following
message will be displayed:
Invalid port-network specified
If the technician-entered carrier is not a valid carrier, the following message will
be displayed:
Invalid carrier specified
If the technician-entered carrier is not active, the following message displays:
Board invalid
If the specified carrier/position processor interface circuit pack is not inserted,
but the specified carrier is active, the following error message will be displayed:
Processor Interface (TN765)
not started or is being started
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed,
then the following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
location The location (cabinet-carrier-position) of the processor interface (PI
board). The position determines which processor interface circuit pack
will be cleared. A position of 1 is the first processor interface in the
carrier, while a position of 2 is the second processor interface in the
carrier.