DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1594UDS1-BD (UDS1 Interface Circuit Pack)
10
1 to 17
(cont’d.)
FAIL
(cont’d.)
If the UDS1 connects to a line-side terminating device
such as a PRI terminal adapter:
1. Retry the command at 1 minute intervals for a
maximum of 5 times.
2. Enter the list measurement ds1-log PCSS
command to read the error seconds measurement.
3. Verify that the switch DS1 and the line-side
terminating device are administered using the same
signaling mode, framing mode, and line coding.
4. Investigate the maintenance status of the line-side
terminating device. Refer to the ’Line-Side
Terminating Device Operating Manual’ for
information.
5. Contact the vendor of the line-side terminating
device to diagnose the equipment.
6. Check the physical connection of the UDS1
interface circuit pack to the terminating device, and
check the premise distribution system (or the
intra-premise wiring) for physical connection
failures.
7. Replace the local UDS1 interface circuit pack and
repeat the test.
PASS No Misframe alarm is detected on the UDS1 Interface
circuit pack.
Table 10-467. TEST #145 Misframe Alarm Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page