Page 8-180list config software-version
8
1. none in memory No update has been applied to memory.
2. immediate partially
applied
An error condition that is valid only when an
update that is in the process of being
applied fails. Check the validity of the
update file that was sent, and then check the
hardware error log for tape errors, and follow
standard maintenance procedures.
3. all immediate
applied deferred
pending
A valid update file was received by the
switch, and all the immediate sub-patches
were applied. This state indicates that there
are deferred sub-patches in the update file,
and a system reset of the proper level has
not occurred since the update file was
received.
4. deferred partially
applied
An error condition that is valid only when a
update that is in the process of being
applied fails. Check the validity of the
update file that was sent, and then check the
hardware error log for tape errors, and follow
standard maintenance procedures.
5. entirely applied to
memory
The update associated with the
memory-resident identifier has been
completely applied to memory.