Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-301CLSFY-PT (Call Classifier Port)
10
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
Tone
Detection Verification Test
, for example, you may also clear errors generated
from other tests in the testing sequence.
Tone Detection Verification Test (#42)
This test checks out each port in both the touch-tone receiver mode and in the
R2-MFC tone detection/generation mode. During the first half of the test, the
touch-tone receiver mode is tested. In the second half of the test, each port is put
into the R2-MFC mode. During this portion of the test, each port’s ability to
accurately detect and generate all forward and backward MFC tones is verified.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long
Test
Sequence D/ND
1
Tone Detection Verification Test (#42) X X ND
Tone Detection Audit/Update Test (#43) X X ND
Table 10-86. TEST #42 Tone Detection Verification Test
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources
needed for this test OR there was an Internal System
Error.
1 ABORT The system could not allocate all the resources needed
to test the tones.
1001 ABORT The system was unable to put the Call Classifier port in
the appropriate mode to test it.
Continued on next page