Maintenance Object Repair Procedures
Page 10-1056PI-LINK (Processor Interface Link)
10
Aux values of concern; any others can be ignored.
e. This error occurs when the Processor Interface link fails to be established.
Check all connections and administration. This could also occur as a
result of another error, the failure of Test #182, for example. If the other
error on the link can be cleared, then this error may also clear. See the
"Link Recovery" section.
2 Link translation error. If the communication-processor link
form indicates this link’s destination is a tac+extension,
then bring up the dial plan form. If an extension exists with
the same first digit as the tac, then this PI link will not
establish. To alleviate this problem, either remove the
extension on the dial plan form, or change the destination
field on the communication-processor link form to use a
UDP extension to dial the far-end.
8 Port not administered in software.
1, 2 System error.
7 System error. If this error is occurring on all administered
links with the same Aux Data and all links are alarmed, then
execute the reset interface command to restore all the
links.
12 One of the two Loop Around Tests failed (#182 or #183).
See the "Link Recovery" section.
13 Hardware problem with DS1 facility is affecting ISDN links.
Refer to DS1-BD Maintenance documentation.
19 A transient state associated with the D-channel backup
protocol. The link is being held in the busy state until call
control can be moved to the new active link. No action
needs to be taken.
Continued on next page