DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-510DIOD-DS1 (DS1 DIOD Trunk)
10
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log.
If present, refer to the UDS1-BD (DS1/UDS1 Trunk
Circuit Pack) Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2053 ABORT At least one of the following errors is found on the DS1
circuit pack:
■ 1281—Loss of signal
■ 1793—Blue Alarm
■ 2049—Red Alarm
■ 2305—Yellow Alarm
■ 1537—Hyperactivity
Look for the above error types in the Hardware Error Log
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for
the listed error types.
Table 10-138. TEST #314 DS1 CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page