DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-25Software Upgrade
5
7. Enter list configuration software-version, and press Enter to compare the
version number of the Release 5.4 software program (displayed on the
terminal) with the TN790 version number (written on a label on the TN790’s
faceplate). If the version numbers are not the same, change the version
number on the TN790 label so that they agree.
8. Perform a sanity check on the system running the new software by
executing the following commands in this order:
a. status system 1 (to check out unusual status in the system)
b. list station (to ensure that the translation is read in properly)
c. display alarm (to ensure no alarm is raised in the system)
d. list trunk-group (to ensure the translation is read in properly)
e. list hunt-group (to ensure the translation is read in properly)
This ensures there is no translation corruption and the translations can be
saved with the new software.
NOTE:
If the new load must be returned to the previous software load,
re-install the TN786B/CPP1 circuit packs and reboot with the
previous version’s translation card.
9. Get the DOSS order number of the upgrade, and call the regional CSA to
request an “init” login. Once logged in as “init,” the CSA should assign the
Release 5.4 option, which automatically sets the 24-hour password aging
for the upgraded system’s customer logins.
NOTE:
Certain forms have changed for DEFINITY ECS R5. Upgraded
translations may appear on a different form, fields may shift within a
form, and the name assignments to particular fields may change.
10. Notify the switch administrator that any previous login names and
passwords still exist, but that the passwords expire in 24 hours. The new
login names and passwords must conform to the requirements below.
NOTE:
A password must have from 4 to 11 alphanumeric characters
including at least 1 alphabetic character and 1 numeric character. A
login name must have from 3 to 6 alphanumeric characters.
11. Since an R1V3.0 G3-MA cannot notify users about expiring passwords,
disable password aging for any login name used with an R1V3.0 G3-MA.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.