DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1104PKT-CTRL (Packet Control Circuit Pack)
10
5 FAIL The SPE could not communicate with the Packet Control circuit pack. This
indicates that either the Packet Control circuit pack is not installed or that it
has failed.
1. Examine the appropriate carrier to determine if there is a Packet Control
circuit pack in the correct slot. If there is, go to the next step. If there
isn’t, the problem is that the Packet Control circuit pack is administered
(that is, the "Packet Bus Activated?" field on the Maintenance-Related
System Parameters Form is set to "y") but the circuit pack isn’t installed.
If the system is supposed to have a Packet Control circuit pack, the
system must be upgraded appropriately (see upgrade documentation).
If the system is not supposed to have a Packet Control circuit pack, then
the Packet Control circuit pack should be unadministered by setting the
"Packet Bus Activated?" field on the Maintenance-Related System
Parameters Form to "n." Refer to the "Maintenance-Related System
Parameters Form" section in Chapter 5, ‘‘
Routine Maintenance
Procedures’’ for more information on the "Packet Bus Activated?" field.
2. Retry the command.
3. If it fails again with the same error code, replace the Packet Control
circuit pack.
Table 10-326. TEST #586 Packet Control Reset Test Continued