DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-515status system
8
■ down/analysis This standby SPE is in down mode and is currently
in the process of performing background maintenance testing in an
effort to determine if the problem has been corrected.
SELECT SWITCH The position of the SPE select switch on the Duplication Interface
circuit pack is displayed in the SPE related information section. The
switch can be in one of three positions:
— auto
The switch is in the position.
— spe-a
The switch is in the left position.
— spe-b
The switch is in the right position.
— <blank>
Always appears for the 1A and 1B SPE in a simplex system. In a
system with High or Critical Reliability, a "blank" implies a
hardware problem with the Duplication Interface circuit pack.
PE ALARMS -
MAJOR
The number of Major alarms associated with the SPE complex that
affect the fault severity level of this SPE is shown. If the system is
simplex system, then the 1B SPE always shows blank.
SPE ALARMS -
MINOR
The number of Minor alarms associated with the SPE complex that
affect the fault severity level of this SPE is shown. If the system is
simplex system, then the 1B SPE always shows blank.
TONE/CLOCK The location of the tone-clock circuit pack. Valid locations are 1A,
1B, 2A, 2B, 3A and 3B.
SERVICE STATE The operational state of the Tone-Clock circuit pack. The possible
states are as follows:
— in
The Tone-Clock is installed in the system and is in-service.
— out
The Tone-Clock has failed certain maintenance tests and has
been removed from service.
— <blank>
If the system is not duplicated, then there is no B carrier
Tone-Clock and this field displays "blank".