Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-649ETR-PT (Enhanced Tone Receiver Port)
10
2006 ABORT This abort code indicates that the active Tone-Clock
circuit pack or a Tone Detector circuit pack may not be
functioning properly. On G3r V2 systems, this abort can
also be caused by a mismatch between the
companding mode administered for the system and that
of the Tone Detector circuit pack.
1. [G3r V2] Make sure that the companding mode of
the system matches that of the Tone Detector:
mu-law for TN748; A-law for TN420.
2. Test the
active
Tone-Clock circuit pack in the port
network with the test tone-clock PC command and
refer to the TONE-BD section for failures.
3. Retry the command at 1-minute intervals a maximum
of five times.
4. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1-122 FAIL DTMF digits were not detected correctly.
1. Run the short test sequence via the test port
PCSSpp sh r 1 command.
2. If the problem persists, the system is still operating
properly but capacity will be reduced. To restore
performance to normal, replace the circuit pack
containing the defective ETR-PT (Enhanced Tone
Receiver Port). Follow the procedures described in
the TONE-BD section for replacing a tone/clock
circuit pack.
Table 10-187. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page