DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-109display communication-interface
8
Establish Connection This field indicates whether the local switch is responsible for
any part of call set-up with the far-end data module. If the
physical link is through a pair of data modules, each switch
terminating the link must set up a connection to its PDM/TDM. If
the physical link is over a DS-1 interface, it is possible for one
switch to set up the entire connection without any initiation by
the other end. However, ISDN signaling links must be set to "y"
at both ends of the interface.
Connected Data
Module
The extension of a PDM/MPDM directly connected to a PGATE
port cable or to a a cable to an adjunct in an administered
connection arrangement.
Identification This field records the type and identification number of the
machine connected to this link. This field is for informational
purposes only.