DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-35busyout spe-standby
8
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
Output
For the following output example the command entered was "busyout sp-link."
Feature Interactions
None.
busyout spe-standby
This command allows the technician to busyout the standby Switch Processing
Element (SPE)
Port Not applicable. Will always be blank.
Maintenance Name The type of maintenance object that is being busied out will
always be SYS-PRNT.
Alt. Name Not applicable. Will always be blank.
Result The result of the busyout - "PASS," "ABORT," "FAIL".
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be found in the
"Busyout/Release Error Codes" section of this chapter.
busyout sp-link SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
SYS-PRNT PASS
Command Successfully Completed