DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Reliability Systems: A Maintenance Aid
Page 6-28Repair Procedures for High and Critical Reliability
6
Figure 6-1. Page 1 Procedure for Replacing Standby SPE Circuit Packs
Issue the
"save translations
spe-active" command
Issue the
"save translations
spe-active" command
Issue the
"upgrade software"
command
Throw the SPE select
switches to
hard-select the
standby SPE and
allow the standby
SPE time to become
active
Throw the SPE select
switches to force an
SPE interchange
Exchange the
active SPE
and STANDBY
SPE memory
cards or tapes
Exchange the
active SPE
and STANDBY
SPE memory
cards or tapes
Throw the SPE select
switches to
hard-select the active
SPE
Unseat the standby
SPE processor circuit
pack
YES
NO
Are there
SHDW-CIR
alarms in the active
SPE or are there
SHDW-LNK
alarms?
C
A
B
YES
YES
YES
NO
NO
NO
Are there
DUPINT alarms
in the active
SPE carrier?
Is
processor
being replaced
and a software
card being
used?
Was the
"upgrade software"
successful?