DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-533test access-endpoint
8
Description
The test access-endpoint command performs hardware diagnostic tests on all
port circuits that are associated with the specified access endpoint.
Defaults
The default for the command is short with repeat number of 1.
Parameters
Help Messages
If the user presses HELP after entering "test access-endpoint", the following
message is displayed:
Enter extension number, [’long’ or ’short’],
[’repeat’ (1-100)], [’schedule’]
Error Messages
If the format for the extension is incorrect, the following error message will be
displayed:
Extension invalid
If the EPN on which the access endpoint resides is not accessible, the following
message will be displayed:
EPN is not available
If the extension is not administered, the following message will be displayed:
extension The extension of the access endpoint to be tested. The number of
digits in an extension is determined by the dial-plan.
short This will cause the command to execute a series of nondestructive
diagnostic tests.
long This will execute a more comprehensive and longer version of
nondestructive diagnostic tests.
repeat number The "number" specifies how many times each test in the sequence is
to be repeated. "Number" may be any integer between 1 and 100.
schedule When the "schedule" option is specified, the command is validated
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed in
the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.