DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1018PDMODULE, TDMODULE (Data Module)
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the
building wiring, through an internal looparound path in the data module under
test, and back to the PBX. Figure 10-75
shows the hardware configuration used
for this test.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS Data Module Audits passed. This digital port circuit
pack is functioning properly.
1. If complaints still exist, investigate by using other
port tests, and by examining the data module
options, wiring, and connections.
Table 10-291. TEST #17 Data Module Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page