DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1387TAPE-DAT (Tape Consistency)
10
84 FAIL The update files, load vintages, and announcements are different in both
SPEs. The Standby SPE has the most current update file and
announcements.
85 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current translations,
and the Standby SPE has the most current update file and announcements.
86 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Standby SPE has the most current update file,
translations, and announcements.
1. Follow the procedures for Error Code #4 to get the correct load
vintage. After running the test tape long command, check for Error
Code #32 or #64. Follow the recovery procedure under the applicable
error code.
PASS The load vintages, translations, announcements, and update files are the
same.
Table 10-419. TEST #421 Tape Data Consistency Check Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page