DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1010PDMODULE, TDMODULE (Data Module)
10
1004 ABORT The port may be busy with a valid call. Use the display
port PCSSpp command to determine the extension of
the data module port. Use the status data-module
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states). You must wait until the
port is idle before retesting.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1020 ABORT Test disabled via background testing. Use status
data-module command to determine when the data
module is available for testing.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort escalate the problem.
2020 ABORT The test did not run due to a previously existing error on
the specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this
port or the circuit pack and attempt to diagnose the
previously existing error.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort escalate the problem.
Table 10-289. TEST #9 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page