Table 10-487. TEST #1100 VC Summer Port
Local TDM Loopback Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available, or the port may
be busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The traffic load on the
system is very high or time slots are out-of-service due to TDM-BUS errors.
Refer to TDM-BUS maintenance documentation to diagnose any active
TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a Tone Detector for the test, the system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port to determine whether the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received from the VC-BD circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports
are not in use. Reset the circuit pack by issuing the busyout board
PCSS and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
0 FAIL The TDM Loop Around Test failed.
1 FAIL The Conference Circuit Test failed.
1. Replace circuit pack.
PASS The VC Summer Port Local TDM Loopback Test passed.