DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-441DID-DS1 (DS1 DID Trunk)
10
Table 10-123. TEST #36 Port Audit and Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port may be busy with a valid call. Issue the display
port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the Error Log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1006 ABORT The test was aborted because the trunk is out of service.
1. Use the status trunk command to verify that the
trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, issue the
release trunk command to put the trunk back in
service, and then retry the test.
4. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test was not received within the
allowable time period.
2100 ABORT Could not allocate resources to run this test.
1. Retry the command at 1 minute intervals for a
maximum of 5 times.
If the test continues to abort, escalate the problem
Continued on next page