DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1114PMS-LINK (Property Management System Link)
10
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to
the extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS The PMS Link is torn down.
Table 10-328. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10
20
ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
30 ABORT Internal System Error.
1. Refer back to the ‘‘
Procedures for Restoring the PMS
Link’’ section for resolution.
1010 ABORT The PMS Link has been busied out and placed in the
out-of-service state.
1. Enter release pms-link command to release the
PMS Link from busyout state.
2. Retry test pms command to execute the test.
Continued on next page
Table 10-327. TEST #213 Link Tear Down Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page