DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1552UDS1-BD (UDS1 Interface Circuit Pack)
10
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the reset board command at 1-minute
intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The UDS1 Interface circuit pack failed in the Internal
Loop Around Test.
If the UDS1 connects to a T1 network facility or another
switch:
1. Retry the reset board command at 1-minute
intervals a maximum of 5 times.
2. Enter the list measurement ds1-log PCSS
command to read the error seconds measurement.
3. Verify that both endpoints of the DS1 link are
administered using the same signaling mode,
framing mode, and line coding.
4. Check the physical connectivity of DS1 Interface
circuit packs and cable.
5. Replace the local UDS1 Interface circuit pack and
repeat the test.
6. Contact T1 Network Service to diagnose the remote
DS1 endpoint.
7. If the test still fails, then escalate the problem.
More information continues on the next page.
Table 10-459. TEST #135 Internal Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation