DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-11busyout data-module
8
Permissions
The following default logins may execute this command: system technician,
inads, cust, init, nms.
Examples
busyout data-module 31300
Description
The busyout data module command will put the specified data module in a
maintenance busy state, even those data modules that are not installed. There
will be no periodic or scheduled tests performed on the busied out data module
or data channel until it is released. Also no call processing may be executed on
the data modules or over the data channels. Warning alarms are generated (error
type 18) on each maintenance object busied out, so that INADS can access the
state of the objects. The release data module command will return the specified
data module (or data channel) to operation.
On a system with the duplication option, a busyout of a Network Control Data
Channel, DATA-CHL, or a Processor Interface Port Data Channels, PI-PT, will be
preserved across SPE interchanges. The data channel extension must be
released before the data channel can be brought back into service.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses HELP after entering "busyout data-module," the
following message will be displayed:
Enter assigned extension
Error Messages
If the length or format of the extension is incorrect, the following error message
will be displayed:
Extension invalid
extension An extension number associated with the desired data module or data
channel. The number of digits in an extension is determined by a
dial-plan.