DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-362CONFIG (System Configuration)
10
As a result of either of these errors, a Port circuit pack may be physically
inserted in a Port slot, but the system may not recognize its existence. The
Error Type and Aux Data fields specify the location of the port circuit pack
that caused the error as indicated in Table 10-100. If the Error Type field is
greater than 1000, subtract 1000 from the Error Type field before
consulting the table.
If more than one CONFIG error is logged with an Aux Data of 1 at the
same time, investigate any EXP-INTF (Expansion Interface) errors before
proceeding.
Once the Port circuit pack location has been determined from Table
10-100, use the list configuration all command to determine if the circuit
pack is inserted. If not, insert the pack. If the circuit pack has already been
inserted but the error persists, replace the circuit pack.
Table 10-100. System Configuration Error Log Entries
Error Type Aux Data Port Circuit Pack Location
1 0 GAMUT Circuit Pack
1
1 1 GAMUT Circuit Pack
1
201E01
212E01
223E01
301E02
312E02
323E02
401E03
412E03
423E03
501E04
512E04
523E04
601E05
612E05
623E05
701E06
712E06
Continued on next page