DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1676XXX-BD (Common Port Circuit Pack)
10
1008 ABORT Could not allocate a ringing circuit for one of the
following reasons: all the ringing circuits are in use; the
ringing generator is defective; ringing generator is not
wired correctly.
1. If the test continues to abort, look for RING-GEN
error in Error Log.
a. If there are RING-GEN errors, refer to RING-GEN
Maintenance documentation and try to resolve
any problem(s). Go to Step 2.
b. If there are no RING-GEN errors, and the test
continues to abort, issue the test board PCSS
command on other TN742, TN769, or TN746
Analog circuit packs. If an ABORT with error code
1008 occurs for this test on other circuit packs as
well, the ringing generator may be defective or
may not be wired properly. Refer to RING-GEN
Maintenance documentation for details. If an
ABORT with error code 1008 does NOT occur on
the other ports, then all four ring generators are in
use. Exit from this documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
FAIL No ringing current is detected. The ringing application
circuitry on this circuit pack probably is not healthy.
1. Retry the command again.
2. If the test continues to fail, look for RING-GEN error
in Error Log.
a. If there are RING-GEN errors, refer to the
RING-GEN Maintenance documentation and try
to resolve any problem(s).
b. If there are no RING-GEN errors, replace the
circuit pack.
3. Retry the command again.
4. If the test continues to fail, escalate the problem.
Table 10-493. TEST #51 Ringing Application Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page