DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-653test shadow-link
8
If the standby SPE is busy with another task, then the following message is
displayed
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the
following message is displayed:
Standby SPE not available;
for information use "status system 1"
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command that was entered
was "test shadow-link"
Feature Interactions
None.
Port The port address will always be blank for this command.
Maintenance Name The maintenance name will always be SHDW-LNK for this
command.
Alt. Name Not applicable.
Test No The test number will always be 318 for this command.
Result The result of the individual test -"PASS," "ABORT," "FAIL,"
"DISABLED,".
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test shadow-link
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
SHDW-LNK 318 PASS
Command Successfully Completed