DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1635UDS1-BD (UDS1 Interface Circuit Pack)
10
PASS The ICSU Status LEDs test executed successfully. A
PASS result, however, does not necessarily mean that
the status LEDs behaved properly. It only means that the
software successfully attempted to light the status LEDs.
This is a visual test. The service technician must visually
exam the behavior of the LEDs while the test is running.
The LEDs are functioning properly if the four status LEDs
are lit red for 5 seconds, then lit green for 5 seconds,
then lit yellow for 5 seconds. If the LEDs behave
differently, the board should be replaced at the
customer’s convenience.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the add ds1 PCSS command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal
ID and the port.
Table 10-477. TEST #1227 ICSU Status LEDs Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page