Maintenance Commands and Trouble-Clearing Aids
Page 8-643test pri-endpoint
8
For the following output example, assume that the port in cabinet 1, carrier c, slot
7, circuit 1 is an analog port. The command that was entered was "test port
1c0701".
Feature Interactions
None.
test pri-endpoint
This command will perform hardware diagnostic tests on all port circuits
(B-channels) that are associated with the PRI endpoint extension.
Synopsis
test pri-endpoint extension
[ short | long ] repeat number schedule
Permissions
The following default logins may execute this command: system technician,
inads, init, nms.
Test No The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the release failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test port 01c0701 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS
Command Successfully Completed