DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-955M/T-ANL (Maintenance/Test Analog Port)
10
Any FAIL The NPE of the tested port was found to be transmitting
in error. This will cause noisy and unreliable
connections.
1. If the remaining ports are currently not in use (yellow
LED is off), try to reset the circuit pack via the
busyout board PCSS, reset board PCSS, release
board PCSS command sequence. Then repeat the
test.
2. If the test fails again, replace circuit pack.
PASS The port is correctly using its allocated time slots.
User-reported troubles on this port should be
investigated by examining station, trunk, or external
wiring.
Table 10-273. TEST #9 NPE Cross Talk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page